Skip to content

GitLab

  • Projects
  • Groups
  • Snippets
  • Help
    • Loading...
  • Help
    • Help
    • Support
    • Community forum
    • Submit feedback
  • Sign in
S src
  • Project overview
    • Project overview
    • Details
    • Activity
    • Releases
  • Repository
    • Repository
    • Files
    • Commits
    • Branches
    • Tags
    • Contributors
    • Graph
    • Compare
    • Locked Files
  • Issues 62
    • Issues 62
    • List
    • Boards
    • Labels
    • Service Desk
    • Milestones
    • Iterations
  • Merge requests 4
    • Merge requests 4
  • CI/CD
    • CI/CD
    • Pipelines
    • Jobs
    • Schedules
  • Operations
    • Operations
    • Incidents
    • Environments
  • Analytics
    • Analytics
    • CI/CD
    • Code Review
    • Issue
    • Repository
    • Value Stream
  • Wiki
    • Wiki
  • Snippets
    • Snippets
  • Members
    • Members
  • Activity
  • Graph
  • Create a new issue
  • Jobs
  • Commits
  • Issue Boards
Collapse sidebar
  • OPAL
  • src
  • Issues
  • #248

Closed
Open
Created Oct 04, 2018 by adelmann@adelmann🎗Owner

Problems with flexible collimator when used with optimizer

I am getting messages like this:

░No reference point provided: using the origin
Individual not viable, I try again: iter= 0
Individual not viable, I try again: iter= 0
░No reference point provided: using the origin
Individual not viable, I try again: iter= 0
Individual not viable, I try again: iter= 1
Individual not viable, I try again: iter= 2

and then the optimisation is killed with

===================================================================================
=   BAD TERMINATION OF ONE OF YOUR APPLICATION PROCESSES
=   PID 61951 RUNNING AT bdw-0026
=   EXIT CODE: 9
=   CLEANING UP REMAINING PROCESSES
=   YOU CAN IGNORE THE BELOW CLEANUP MESSAGES
===================================================================================
   Intel(R) MPI Library troubleshooting guide:
      https://software.intel.com/node/561764
===================================================================================

No further information !

All simulation in progress, at the time when the optimisation is killed, are terminating just fine.

There is the new flexible collimator involved and a constraint w.r.t. number of particles.

When removing the flexible collimator the optimisation works just fine.

Will add input files later. Need to catch my airplane now!

Edited Oct 29, 2018 by kraus