- 14 Jan, 2013 3 commits
- 09 Jan, 2013 1 commit
-
-
https://amas.psi.ch/OPAL/ticket/100adelmann authored
From https://amas.psi.ch/OPAL/ticket/100 fix start of collimator and remove duplicated code i.e. use the Collimator object in CollimatorPhysics.cpp
-
- 08 Jan, 2013 2 commits
-
-
adelmann authored
in svn+ssh://savannah02.psi.ch/repos/opal/tests/trunk/Collimator - Now we have to check again aginst FLUKA and mabe mcmpx (ToDo: Y. Bi) - In the collimator physics class the start of the collimator in floor coordinates is wrong is always 0.0 (ToDo: A. Adelmann) - In the collimator physics class there is a duplocation of the actual collimator code, this needs to be elliminated (A. Adelmann) - One has to check the CCollimator (ToDo: J. Yang)
-
adelmann authored
-
- 07 Jan, 2013 1 commit
-
-
adelmann authored
energy spectrum, but something with the beams x,z,y coordinates is still wrong. I guess it is a units problem in CoulombScat. Check the test in opal-tests/Collimator
-
- 28 Dec, 2012 1 commit
-
-
adelmann authored
-
- 05 Dec, 2012 1 commit
-
-
adelmann authored
-
- 03 Dec, 2012 1 commit
-
-
adelmann authored
-
- 02 Dec, 2012 2 commits
- 29 Nov, 2012 5 commits
- 24 Oct, 2012 1 commit
-
-
adelmann authored
fix a case reported by Chris where we loose a particle which is still epsilon out of the field in z-direction
-
- 18 Oct, 2012 2 commits
-
-
Jianjun Yang authored
Add a new parameter OPYIELD (the outcome particle number per income particle) for STRIPPER element, opyield=2 for H2+; opyield=1 for H-
-
Jianjun Yang authored
-
- 13 Sep, 2012 1 commit
-
-
adelmann authored
-
- 07 Sep, 2012 1 commit
-
-
adelmann authored
-
- 06 Sep, 2012 2 commits
- 05 Sep, 2012 2 commits
- 04 Sep, 2012 1 commit
-
-
gsell authored
-
- 31 Aug, 2012 1 commit
-
-
gsell authored
-
- 30 Aug, 2012 2 commits
- 25 Aug, 2012 1 commit
-
-
adelmann authored
-
- 24 Aug, 2012 5 commits
- 23 Aug, 2012 2 commits
- 09 Aug, 2012 2 commits