Premature termination of integration when reference particle after MAXSTEPS in implicit drift.
The Degrader-1 test is flagged as broken because the number of saved steps in the .stat
file differ. This is caused by the fact that after 230 steps (MAXSTEPS) the reference particle in the OrbitThreader class is located in a drift, that isn't explicitly mentioned in the input file. During simulation ParallelTTracker stops because it seems to have reached the end of the beamline.